Ethernet standards and speeds: reading names like 1000BASE-T and 10GBASE-SR, auto-negotiation and multigigabit
In short: Ethernet standard names tell you the speed, the signalling and the medium: 1000BASE-T is 1 Gbps over twisted-pair copper, 10GBASE-SR is 10 Gbps over short-reach multimode fibre. Copper ports agree speed and duplex with auto-negotiation and fix cable wiring with auto-MDIX. Multigigabit 2.5 and 5 Gbps run on existing Cat5e and Cat6 cable for Wi-Fi access points.
Reading the name
Ethernet standards come from the IEEE 802.3 working group. Their names follow a pattern:
- The number is the speed: 100 is 100 Mbps, 1000 is 1 Gbps, 10G is 10 Gbps.
- BASE means baseband signalling (one signal on the medium).
- The suffix describes the medium: T = twisted pair, SX/SR = short-wave multimode fibre, LX/LR = long-wave (usually single-mode), CR = copper twinax (DAC), KR = backplane.
Common standards
| Name | Speed | Medium | Reach |
|---|---|---|---|
| 100BASE-TX | 100 Mbps | Cat5 copper | 100 m |
| 1000BASE-T | 1 Gbps | Cat5e copper | 100 m |
| 1000BASE-SX / LX | 1 Gbps | Multimode / single-mode | 550 m / 10 km |
| 2.5GBASE-T / 5GBASE-T | 2.5 / 5 Gbps | Cat5e / Cat6 copper | 100 m |
| 10GBASE-T | 10 Gbps | Cat6A copper | 100 m |
| 10GBASE-SR / LR | 10 Gbps | Multimode / single-mode | 300-400 m / 10 km |
| 25GBASE-SR / CR | 25 Gbps | Multimode / DAC | 100 m / a few m |
| 100GBASE-SR4 / LR4 | 100 Gbps | MPO multimode / single-mode | 100 m / 10 km |
Auto-negotiation
When two copper ports connect, they exchange "fast link pulses" listing the speeds and duplex modes they support, and pick the best common one. This should be left on for almost everything. The famous problem is when one side is fixed (for example speed 100, duplex full) and the other is set to auto: the auto side cannot detect duplex, falls back to half duplex, and you get a duplex mismatch. Symptoms are a link that works but is very slow, with late collisions on the half-duplex side and CRC errors on the full-duplex side. Either set both ends to auto (best) or both fixed.
Fibre links do not auto-negotiate speed in the same way; both ends must use the same speed optic.
Auto-MDIX
Old Ethernet needed crossover cables between two switches or two PCs. Nearly every modern port detects which pairs to transmit and receive on (auto-MDIX), so any straight-through cable works.
Multigigabit
Wi-Fi 6 and 7 access points can pass more than 1 Gbps, but rewiring buildings for 10GBASE-T is expensive. 2.5GBASE-T and 5GBASE-T (from the NBASE-T effort, now IEEE 802.3bz) run over existing Cat5e and Cat6 cable at up to 100 m. Multigigabit switch ports (often labelled mGig) negotiate down to the best speed the cable supports.
Checking speed and duplex
- Cisco:
show interfaces statusshows a-full / a-1000 (auto-negotiated values) or fixed values. - Windows:
Get-NetAdapter | Format-Table Name, LinkSpeed. - Linux:
ethtool eth0.
Real-world example: the slow server
A file server felt slow for one department only. The switch port had been hard-coded to 100 Mbps full duplex years earlier for an old device, and the new server's NIC was on auto. It negotiated 100 Mbps half duplex. Setting the switch port back to auto brought the link up at 1 Gbps full duplex and the complaints stopped.
Practice
What does 10GBASE-LR mean?
What happens when one side is fixed at full duplex and the other side is set to auto?
What is the benefit of 2.5GBASE-T and 5GBASE-T?
Key takeaways
- Ethernet names show speed, BASE signalling and medium (T, SR, LR, CR).
- Leave auto-negotiation on at both ends to avoid duplex mismatches.
- Auto-MDIX removes the need for crossover cables.
- Multigigabit 2.5 and 5 Gbps runs over existing Cat5e and Cat6.
Original content written by Mohamed Fayas for FM TecHub. © 2026 FM TecHub. You're welcome to share a link to this page; please don't copy the text elsewhere without permission.