Designing network redundancy: removing single points of failure without adding complexity
In short: Redundancy means no single failure stops an important service. It applies to power, devices, links, physical cable routes, providers, sites and the services the network depends on, such as DNS and RADIUS. Look for hidden shared dependencies, such as two links in the same duct, and keep the design simple: complex redundancy often fails in surprising ways.
Find the single points of failure
A single point of failure (SPOF) is any component whose failure stops a service. Draw the path from a user to an important application and ask, for every box and line, "what happens if this fails?" You will usually find SPOFs in unexpected places: a single internet router, one core switch power supply, the only DHCP server, or one person who knows how the firewall works.
Levels of redundancy
- Power: dual power supplies fed from different circuits, UPS, generator for critical sites.
- Devices: core and distribution in pairs, access switches in stacks, firewalls in HA pairs.
- Links: at least two uplinks, bundled with LACP or used with ECMP so both carry traffic.
- Physical paths: the two fibres between buildings should take different routes into different comms rooms where possible.
- Providers: internet or WAN links from two carriers, ideally using different physical infrastructure.
- Sites: a second data centre, a cloud region or a recovery site for critical services.
- Network services: two DNS, DHCP (failover), NTP, RADIUS/ISE and wireless controllers.
Hidden shared risk
Two links can look redundant on a diagram but share a common risk: both fibres in the same trench, both carriers buying the last mile from the same wholesale network, both "diverse" switches in the same rack on the same power strip, or both firewalls running the same buggy software version. Ask carriers for route maps, check that "diverse" circuits really are, and record shared-risk groups in your documentation.
Active/active or active/standby?
- Active/active uses both paths all the time (ECMP, LACP, GLBP, SD-WAN). You use the capacity you paid for, and you know both paths work. But each path must be able to carry the full load during a failure.
- Active/standby keeps one path idle (HSRP, floating routes, firewall HA). Simpler to reason about, but a standby path may have failed silently. Monitor it and test it.
Keep it simple
Every extra protocol and feature added for redundancy is another thing that can fail or be misconfigured. Classic examples are spanning tree loops in heavily redundant Layer 2 designs and split-brain clusters. Prefer simple, well-understood designs: routed links with ECMP, multichassis link aggregation, standard HA pairs. Document how failover is supposed to work.
Test it
Redundancy that has never been tested is a hope, not a design. During maintenance windows, pull a cable, power off a switch, fail over the firewall and measure what users experience. Fix what does not behave as expected.
Real-world example: two carriers, one trench
A company bought internet lines from two different providers for resilience. When road works cut a duct outside the building, both lines went down at once. Both providers' fibres entered the building through the same duct from the same street. The fix was a new entry point on the other side of the building for one carrier, confirmed with route maps, and a 5G backup as a third path.
Practice
What is a single point of failure?
Give an example of hidden shared risk between two "redundant" links.
What must be true of each path in an active/active design?
Key takeaways
- Trace important paths and remove single points of failure.
- Cover power, devices, links, paths, providers, sites and services.
- Look for hidden shared risk such as common ducts or providers.
- Keep redundancy simple, document it and test failover regularly.
Original content written by Mohamed Fayas for FM TecHub. © 2026 FM TecHub. You're welcome to share a link to this page; please don't copy the text elsewhere without permission.