In short: Switches use pluggable transceivers so the same port can connect to different fibre types and distances. The form factor (SFP, SFP+, SFP28, QSFP) sets the speed; the optic type (SR, LR, ER, BiDi) sets fibre type and distance. Direct attach cables are cheap for short links in a rack, and digital optical monitoring shows transmit and receive power for troubleshooting.

Why pluggable

A switch with SFP ports does not care whether you are connecting a server three metres away or a building three kilometres away. You choose a transceiver (also called an optic or module) for each port to match the cable and distance. If a transceiver fails, you replace it without replacing the switch.

Common pluggable transceiversSFP1 GbpsSFP+10 GbpsSFP2825 GbpsQSFP+40 GbpsQSFP28100 GbpsQSFP-DD / OSFP400 and 800 Gbps
Figure 1. The form factor sets the speed; the optic type (SR, LR, ER, BiDi) sets distance and fibre type.

Form factors and speeds

  • SFP: 1 Gbps (also used for 1 Gbps copper RJ45 modules).
  • SFP+: 10 Gbps. Same size, so most SFP+ ports also accept SFP modules at 1 Gbps.
  • SFP28: 25 Gbps, common for servers in modern data centres.
  • QSFP+ / QSFP28: 40 and 100 Gbps, using four lanes. Can often be broken out into four 10 or 25 Gbps links with a breakout cable.
  • QSFP-DD and OSFP: 400 and 800 Gbps in large data centres.

Optic types (the letters)

TypeFibreTypical reach
SR (short reach)Multimode, 850 nmup to 300-400 m at 10G (OM3/OM4)
LR (long reach)Single-mode, 1310 nm10 km
ER (extended reach)Single-mode, 1550 nm40 km
ZRSingle-mode, 1550 nm80 km
BiDiOne fibre, two wavelengthsSaves fibre; must be used in matched pairs

Both ends of a link must use matching types: an SR optic will not talk to an LR optic. BiDi modules come in "upstream" and "downstream" pairs that use opposite wavelengths.

DAC and AOC cables

  • Direct attach copper (DAC): a twinax cable with a transceiver built into each end. Cheap, low power and very low latency, for links up to about 3 to 5 metres, such as server to top-of-rack switch.
  • Active optical cable (AOC): similar, but with fibre between the ends, for runs up to about 30 metres.

Compatibility

Switch vendors often check the transceiver's coded ID, and some refuse or warn about "unsupported" third-party optics. On Cisco IOS, service unsupported-transceiver allows them, though support contracts may not cover problems they cause. Reputable third-party suppliers sell optics coded for each vendor at a much lower price, and many organisations use them successfully.

Reading optical levels

Most modern optics support digital optical monitoring (DOM or DDM), which reports temperature, voltage, and transmit and receive power:

show interfaces TenGigabitEthernet1/1/1 transceiver detail

Compare receive power with the optic's specified range. A 10GBASE-LR optic, for example, typically transmits around -1 dBm and works with receive levels down to about -14 dBm. Readings near the bottom of the range, or alarms, point to dirty connectors, damaged fibre or too much distance.

Real-world example: two optics that would not link

A new 10 Gbps link between two switches stayed down although both ends had optics and the fibre tested fine. The DOM output showed light being received at both ends. One end had an SFP-10G-SR and the other an SFP-10G-LR from a box of spares, running over single-mode fibre. Replacing the SR with an LR brought the link up immediately.

Practice

Which transceiver form factor is used for 25 Gbps server connections?
SFP28.
Can a 10GBASE-SR optic link with a 10GBASE-LR optic?
No. SR uses multimode at 850 nm and LR single-mode at 1310 nm; both ends must match.
What is a DAC cable best used for?
Short, cheap, low-latency links of a few metres, such as servers to a top-of-rack switch.

Key takeaways

  • Form factor sets speed: SFP, SFP+, SFP28, QSFP+, QSFP28, QSFP-DD.
  • Optic type sets fibre and distance: SR, LR, ER, ZR, BiDi; both ends must match.
  • DAC and AOC cables are cheap for short in-rack links.
  • DOM readings show transmit and receive power for troubleshooting.
Tracks your learning on this device only. See your progress on the learning paths.
Verified author✓ Valid
Issued to
Mohamed Fayas
Role
Founder of FM TecHub
Credentials
CCNABTEC HND Network EngineeringBEng (Hons) Computer Networking & Cloud Security
Issuer
FM TecHub · fmtechub.com

He writes practical, plain-English guides on networking, security and cloud.

More about the author →

Original content written by Mohamed Fayas for FM TecHub. © 2026 FM TecHub. You're welcome to share a link to this page; please don't copy the text elsewhere without permission.

Email updates: coming soon

New notes, tools and security news from FM TecHub by email, explained simply. Free. We're not collecting email addresses yet; see our privacy policy.

PortServiceStatus
SMTP/25Email updatesopening soon

Meanwhile, stay connected: