Power over Ethernet standards and budgets: PoE, PoE+, PoE++ and planning switch power
In short: Power over Ethernet sends power over the same twisted-pair cable as data, so phones, access points and cameras need no local power adapter. 802.3af gives up to 15.4 W per port, 802.3at (PoE+) 30 W, and 802.3bt (PoE++) 60 or 90 W. Every switch has a total PoE budget, and planning it, along with UPS capacity, prevents devices from failing to power up.
One cable for power and data
A PoE switch (the power sourcing equipment, PSE) detects whether a connected device (the powered device, PD) can accept power, then supplies DC voltage (around 44 to 57 V) over the cable pairs. IP phones, Wi-Fi access points, CCTV cameras, door entry systems, small switches and even some lights run this way. One UPS in the comms room then keeps all of them working in a power cut.
Standards and classes
| Standard | Common name | Power at switch port | Power at device | Typical devices |
|---|---|---|---|---|
| 802.3af | PoE | 15.4 W | 12.95 W | IP phones, basic cameras |
| 802.3at | PoE+ | 30 W | 25.5 W | Wi-Fi 5/6 APs, PTZ cameras |
| 802.3bt Type 3 | PoE++ / UPOE | 60 W | 51 W | Wi-Fi 6E/7 APs, video phones |
| 802.3bt Type 4 | PoE++ / UPOE+ | 90 W | 71 W | Displays, lighting, small switches |
Devices announce a class (0 to 8) during detection so the switch knows the maximum they need. Many also use LLDP-MED to request the exact power they need, which lets the switch reserve less than the class maximum.
The switch budget
Every PoE switch has a total power budget, set by its power supplies, for example 740 W on a 48-port switch with one supply. Ports are powered in order until the budget runs out. If you plug in more devices than the budget allows, the last ones get no power, or the switch drops low-priority ports.
Example: 24 phones at 7 W, 10 APs at 25 W and 6 cameras at 13 W need 168 + 250 + 78 = 496 W. A 370 W switch is not enough; a 740 W switch is, with room to grow.
Useful commands and features
show power inline
show power inline GigabitEthernet1/0/5 detail
interface GigabitEthernet1/0/48
power inline priority high
power inline static max 30000
- Priority decides which ports keep power if the budget is exceeded.
- Static reserves power for a port so it is always available.
- Perpetual and fast PoE (on many Catalyst switches) keep power flowing during a switch reboot, or restore it before the operating system finishes loading.
Common problems
- A new AP keeps rebooting or runs with some radios off: it needs PoE+ or PoE++ but the port only gives PoE.
- Devices fail when a second power supply fails: the budget was counted with both supplies.
- Long or poor-quality cables, especially copper-clad aluminium (CCA), heat up and lose power; use solid copper.
- Remember the UPS: the PoE load adds to the switch's own power draw.
Real-world example: cameras that went dark at night
A warehouse added infrared heaters to its outdoor cameras for winter. At night, when the heaters switched on, several cameras on the far end of the switch rebooted repeatedly. The extra draw pushed the switch over its PoE budget, and it dropped the lowest-priority ports. Adding a second power supply to double the budget, and setting the cameras to high priority, kept them running.
Practice
How much power does a PoE+ (802.3at) port provide at the switch?
Why might a new Wi-Fi 6E access point keep rebooting on an older switch?
What does PoE port priority control?
Key takeaways
- PoE sends power and data over one cable to phones, APs and cameras.
- 802.3af 15.4 W, 802.3at 30 W, 802.3bt 60 or 90 W at the port.
- Add up device power to make sure the switch budget and UPS are large enough.
- Use port priority, static allocation and good-quality copper cable.
Original content written by Mohamed Fayas for FM TecHub. © 2026 FM TecHub. You're welcome to share a link to this page; please don't copy the text elsewhere without permission.