How switches forward frames: store-and-forward, cut-through, buffers and microbursts
In short: A store-and-forward switch receives a whole frame and checks it before sending it on, while a cut-through switch starts sending as soon as it reads the destination address. Both are very fast today. More often, problems come from buffers: when traffic from fast or many ports converges on one slower port, short bursts can overflow the buffer and drop packets even when average usage looks low.
Two ways to forward
Every switch looks up the destination MAC address to decide where a frame goes. The question is when it starts sending.
- Store-and-forward: the switch receives the entire frame, checks the frame check sequence (FCS), then forwards it. Corrupted frames are dropped at the first switch. Latency includes the time to receive the whole frame: about 12 microseconds for a 1,500-byte frame at 1 Gbps, about 1.2 microseconds at 10 Gbps.
- Cut-through: the switch starts forwarding once it has read the destination address. Latency is lower and fixed, but a corrupted frame is passed on and only dropped by the receiving device. Many data centre switches use it, and fall back to store-and-forward when the input is slower than the output.
For offices and campuses the difference is not noticeable. It matters in high-frequency trading, storage and high-performance computing.
Buffers
A switch port can only send at its line rate. If two 1 Gbps ports both send to a third 1 Gbps port at full speed, half the traffic has nowhere to go immediately. The switch stores it in a buffer (memory) and sends it as soon as it can. If the buffer fills, further frames are dropped. Common situations:
- Many to one: many clients sending to one server at once (sometimes called incast).
- Speed mismatch: a 10 Gbps server sending to a 1 Gbps client or uplink.
- Uplink congestion: 48 access ports sharing two uplinks.
Campus switches usually have a few megabytes of shared buffer; data centre and WAN-edge switches can have much more ("deep buffers").
Microbursts
Interface graphs usually average traffic over one or five minutes. A link that shows 20 percent average usage can still have bursts of a few milliseconds at 100 percent, which fill the buffer and drop packets. These microbursts are invisible on normal graphs but show up as rising output drops and as TCP retransmissions on the hosts.
Spotting drops
show interfaces GigabitEthernet1/0/48 | include drops|rate
show interfaces counters errors
show platform hardware fed switch active qos queue stats interface Gi1/0/48
"Total output drops" rising while the five-minute rate looks modest is the classic sign. Fixes include faster uplinks, more uplinks in an EtherChannel, QoS to protect important traffic, adjusting buffer allocation on platforms that allow it, or spreading the load.
Real-world example: backups that broke video calls
At night, a backup server with a 10 Gbps connection pulled data from dozens of servers, and the 1 Gbps link to a branch dropped packets. During the day, the same link looked half empty, but video calls from the branch still stuttered whenever someone opened a large file from the server. Output drops on the 1 Gbps port showed microbursts from the 10 Gbps server. Shaping the server's traffic towards the branch and adding a QoS priority queue for voice and video fixed the calls.
Practice
What does a store-and-forward switch do that a cut-through switch does not?
What is a microburst?
Which interface counter suggests buffer overflows on a switch port?
Key takeaways
- Store-and-forward checks whole frames; cut-through forwards after the header.
- Buffers absorb short bursts when traffic converges on one port.
- Microbursts cause drops that average graphs do not show.
- Watch output drops and fix with capacity, EtherChannel, QoS or shaping.
Original content written by Mohamed Fayas for FM TecHub. © 2026 FM TecHub. You're welcome to share a link to this page; please don't copy the text elsewhere without permission.